4-24 DocuTech 128/155/180 HighLight Color Installation Planning Guide
Prepare for installation
Printer hardware specifications and requirements summary
The following table summarizes the specifications and electrical
requirements of your printer hardware components.
Table 4-8. Printer specifications and power requirements
Device Dimensions (width and
depth)
Total
Weight
Heat dissipation Power requirements
Printer/HLC
with inter-
poser and
finisher
(DT 180 HLC
production
publisher)
W=203.5 in / 516.8 cm
D=42 in / 106.6 cm (with all
front and rear covers)
Total space required
(plus access):
293.1 in (W) x 142.0 in (D) /
744.5 cm x 360.6 cm
3724 lbs
1689 kg
Operating:
32,770 BTU per
hr.
Standby:
4,454 BTU per
hr.
Energy Saver:
2,700 BTU per
hr.
60 Hz
120/240 VAC or 120/
208 VAC; 50 amp
service; NEMA L14-
50R; KVA 7.3
(operating)
(2 Cords required)
120/208 VAC (182 V to
220 V), KVA 7.3
(operating)
Cord 1: 50 amp,
NEMA 14-50R
Cord 2: 30 amp,
NEMA 14-30R
50 Hz:
Consult your local
service representative.
Kommentare zu diesen Handbüchern